Solution and Case

Intelligent field of surge protector solutions experts

Solution

With the development of the national low carbon strategy, new energy is rising rapidly, among which photovoltaic grid connected power generation is developing rapidly and maturely in various places, power generation efficiency is constantly improving, and system voltage is also diversified. The battery panel components should be exposed to the sun to the greatest extent, so that the outdoor equipment and PV system can achieve the highest efficiency. However, this situation also increases the potential lightning risk. When lightning strikes, downstream components, such as connectors, inverters and control instruments, are often destroyed by lightning current in addition to battery panel components. In order to ensure the normal operation of the photovoltaic system, it is particularly important to install surge protective devices at key locations of the photovoltaic system.


For photovoltaic power generation system, Reske launched a surge protector dedicated to photovoltaic. The photovoltaic surge protector is in a high resistance state under normal conditions. When over-voltage occurs in the system, the Reske LM-PVD series photovoltaic special surge protector is turned on in nanoseconds. The surge energy is introduced to the ground through the grounding line, and the amplitude voltage is clamped within the safe and normal range of the equipment. At the same time, the surge energy is introduced to the ground through the grounding line. After the discharge of the surge energy, the surge protector quickly recovers to the high resistance state, thus ensuring the normal operation of the photovoltaic system.


Selection Table of Reske PV Surge Protector

Installation position DC combiner box inverter DC side inverter AC side box transformer

Model LM-PVD40/3P LM-CSV05 LM-PVD40/3P LM-XC385-40/750//3P or 4P LM-XB385-80/750/3P or 4P

Maximum continuous operation voltage VDC Optional: 1000/1200/1500VDC 8V Optional: 1000/1200/1500VDC Optional: 385/690/750VAC Optional: 385/690/750VAC

Nominal discharge current KA 20KV

10KV

20KV

20KV

40KV

Maximum discharge current KA 40KV

20KV

40KV

40KV

80KV

Voltage protection level Up 3.0/3.6/4.0KV 40V 3.0/3.6/4.0KV 1.5/2.3/2.8KV 2.2/2.6/3.2KV

Installation method 35mm guide rail 35mm guide rail 35mm guide rail 35mm guide rail 35mm guide rail

Technical characteristics

Large discharge energy, fast response speed and low residual pressure

Built in overheat overcurrent tripping device, safe and reliable

Y-type circuit design realizes full protection of positive pole to ground, positive pole to negative pole and negative pole to ground

Plug in mode structure, easy to install and maintain, and can be replaced with electricity

With remote signaling function and operation indication function

The shell is made of anti-corrosion and reinforced hot-melt flame retardant materials

Use photovoltaic DC system of 1500V and below